What are the principles of IFT Treatment?
The elementary principle of Interferential Treatment (IFT) is to use the substantial physiological effects of low-frequency stimulation. Lately, plentiful ‘portable’ interferential machines have become easily obtainable with IFT Machine Suppliers. Notwithstanding their size, they are seamlessly capable of distributing ‘proper’ interferential treatment, however, some have limited functionality and ability for the doctor to ‘set’ all strictures. Most multifunction stimulators include all interferential styles, so the doctor has several machine kinds to choose from.
Interferential Treatment (IFT / IFC) has been extensively used in therapy for many years, Its use is probably lopsided to both the volume and the quality of the printed evidence, though it is powerfully supported on an anecdotal evidence level, and numerous reviews are demonstrating an overall supportive indication base, especially for pain based organization.
PRINCIPLES
To yield low-frequency effects at adequate intensity and adequate depth, patients can knowledge substantial uneasiness in the surface tissues (i.e. the skin). This is due to the impedance of the skin being contrariwise compared to the incidence of the stimulation. [The barrier offered by the skin to the route of an electric current is more intricate than just impedance, or resistance, but will be observed as such for the steadfastness of this explanation] In other words, the inferior the stimulus frequency, the greater the impedance to the passage of the current & so, more uneasiness is felt as the current is ‘pushed’ into the tissues against this wall. The skin impedance at 50Hz is about 3200W whilst at 4000Hz it is abridged to about 40W. The consequence of applying a higher incidence is that it will pass more easily through the skin, necessitating less electrical vigor input to reach the deeper tissues & giving rise to less uneasiness. The effects of tissue stimulus with these 'medium frequency' currents (medium incidence in electromedical terms is typically considered to be 1KHz-100KHz) have yet to be recognized. It is improbable to do nothing at all, but in terms of present practice, little is known of its physiological effects. It is not accomplished of the direct stimulus of nerve in the common setting of such stimulus, though some researchers are presently examining this area.
Interferential treatment done on equipment bought from IFT Machine Dealers uses two of these medium incidence currents, passed through the tissues concurrently, where they are set up so that their trails cross & they interlope with each other – hence another term that has been used in the historical but appears to be out of courtesy at the moment – Interference Current Treatment. This communication gives rise to a meddling current (or beat incidence) which has the features of low-frequency stimulus – in effect the interference copycats a low-frequency stimulation.
The exact incidence of the resultant beat incidence can be controlled by the input incidences. If for instance, one current was at 4000Hz and its buddy current at 3900Hz, the ensuing beat incidence would be at 100Hz, carried on a medium incidence 3950Hz amplitude modulated current. By careful operation of the input currents, it is likely to attain any beat incidence that you might wish to use clinically. Modern machines supplied by IFT Machine Suppliers typically offer incidences of 1-150Hz, nevertheless, some offer a choice of up to 250Hz or more. To a superior extent, the therapist does not have to concern themselves with the input incidences, but merely with the suitable beat incidence which is nominated directly from the machine. The scale of the low-frequency interference current is (in concept) roughly equal to the sum of the effort amplitudes.